STEP→STL Your file stays in this tab · nothing is uploaded

How many triangles does a part need? Budget by curvature, not size

You picked a quality setting, the converter is not asking for anything else, and the question underneath is whether the mesh it is about to write is fine enough for the print — or whether you are about to pay for smoothness a flat part cannot use. Every number on this page was measured on the machine that wrote it and re-run by npm test before the page was published.

The short answer

Budget triangles where the curvature is: flat faces are exact at any setting, curved faces are where the count moves, and the output's byte size — not the model's size — tells you what you got. A part with only flat faces costs exactly 12 triangles — six faces, two per face — at Draft, Normal and Fine alike, so on such a part the quality choice is free. Curved faces are the opposite: the same cone measures 286 triangles at Draft, 516 at Normal and 2,142 at Fine, a 7.5× spread produced by nothing but the tolerance choice. “Enough” is judged at the curved faces: convert once, then read the count back out of the file — a binary STL is 84 bytes of header plus 50 bytes per triangle, so (size − 84) ÷ 50 is the triangle count, and there is no rounding in that identity to hide a fault behind.

The budget: triangles are spent where curvature is

Three shapes cover the decision. Each row is the same file converted at the three shipped settings with this engine, and the last column is what the setting choice is worth on that shape:

Triangle counts measured with this engine in Node.js; npm test re-runs every cell. The full seven-file table, with byte columns, lives on the workflow page.
ShapeDraftNormalFineFine ÷ Draft
All-flat part (a cube)1212121.0×
Cube with rounded edges40561403.5×
Curved surface (a cone)2865162,1427.5×

Read the rows as a budget, not a menu. On the flat cube the setting changes nothing: flat faces are stored exactly, two triangles per face, and any count above 12 on such a part is spend with nothing to show for it. On the rounded cube only the rounded edges respond — 40 to 140 triangles — while the six flat faces keep their 12. On the cone everything responds, and Draft to Fine is a factor of 7.5. Underspending on a curved face is what shows up in the print as visible facets; overspending on a flat face is bytes for nothing. What the counts mean in bytes is drawn out on the file-size page.

Where the triangles are spent: the same three shapes at the Fine preset Three horizontal bars on one scale of one pixel to five triangles. The all-flat cube is twelve triangles, drawn two pixels wide. The cube with rounded edges is one hundred and forty triangles, drawn twenty-eight pixels. The cone is two thousand one hundred and forty-two triangles, drawn four hundred and twenty-eight pixels. Where the triangles are spent: the same three shapes, all at Fine Bars drawn to count ÷ 5 px, the scale used in the drawing below. 1 px = 5 triangles. 12 — all-flat part (a cube) the setting is free here: 12 triangles, 684 bytes, at every preset 140 — cube with rounded edges only the rounded edges respond; the six flat faces still hold their 12 2,142 — curved surface (a cone) The first bar is drawn at its true width: two pixels. That is what “free” looks like — and why a big triangle count is a curved-face bill, not a fault.
Same preset, three bills. All three bars are Fine, and the widths differ by a factor of 214: twelve triangles on the flat part, 140 once curvature enters at the edges, and 2,142 when a whole surface is curved. The count is a property of the geometry you fed the tool, not of how carefully you set the preset — which is why judging “enough” means looking at the curved faces before the cut, not at the file size.

What the budget costs, in bytes

The table above counts triangles; this one prices them. Each cell is the binary-STL identity applied to the engine’s live count for that shape and preset — 84 + 50 × triangles — so no cell is copied from anywhere, and npm test re-earns every one from the sample files. The last column names who set the number, because the three owners are not the same: the format sets the 84 and the 50, the geometry sets the count, and this page’s presets set how much of a curved face the count spends. Only the third is ours to change.

The same three shapes, in triangles and in bytes, at the three shipped presets. Bytes are 84 + 50 × triangles, computed here from the engine’s own counts, not read off any tool’s report.
ShapeDraftNormalFineWho sets it
All-flat part (a cube)12 tri → 684 B12 tri → 684 B12 tri → 684 BFormat only: flat faces are exact, so the preset has nothing to spend
Cube with rounded edges40 tri → 2,084 B56 tri → 2,884 B140 tri → 7,084 BGeometry at the edges; the preset sets how finely the arc is cut
Curved surface (a cone)286 tri → 14,384 B516 tri → 25,884 B2,142 tri → 107,184 BGeometry plus the preset’s deviation pair, both working at once

What the ledger makes visible is the size of the decision. Between Draft and Fine the flat part’s bill moves by zero bytes, the rounded cube’s by 5,000, and the cone’s by 92,800 — same three presets, same writer, same identity, three different prices for the same click. That is why the preset question is a curvature question: on a part with curved faces the choice is a real purchase, and on a part without them it is a label. The deviation pair behind those three columns (0.02 / 0.005 / 0.001 linear, 0.5 / 0.3 / 0.1 angular) are this page’s own choices, not a CAD standard, and the count they produce is checkable afterwards: the back-solve on the verification page recovers it from the finished bytes, and only holds for a binary STL — the two writers are compared on the binary-or-ASCII page. Which of those bytes are a format’s and which are a choice is exactly the split drawn on the STEP-versus-STL page, and what a smaller bill buys you is measured on the file-size page.

Four reproducible arithmetic lines behind the byte table above
Flat part12 triangles at every preset → 84 + 50 × 12 = 684 bytes, three times over — a draft-to-fine gap of 0 bytes.
Rounded edges40 / 56 / 140 triangles → 2,084 / 2,884 / 7,084 bytes; the preset is worth 5,000 bytes on this part.
Cone286 / 516 / 2,142 triangles → 14,384 / 25,884 / 107,184 bytes; Draft to Fine is a 92,800-byte gap.
Back-solve(7,084 − 84) ÷ 50 = 140 and (107,184 − 84) ÷ 50 = 2,142: the ledger runs in both directions.
The Draft-to-Fine bill for three shapes, drawn on one byte scale Three bars share one scale of 1 pixel = 200 bytes. A flat cube moves 0 bytes between Draft and Fine, a rounded cube moves 5,000 bytes, and a cone moves 92,800 bytes. The counts behind them are the same ones in the ledger above. Same click, three bills Draft to Fine, in bytes, on one scale: 1 px = 200 bytes flat part 0 B — nothing to spend rounded cube 5,000 B cone 92,800 B Same three presets, same writer; only the curvature differs.
The same preset change, priced three ways. Between Draft and Fine the flat cube moves 0 bytes, the rounded cube 5,000, and the cone 92,800 — all three read off the ledger above, not from any tool’s report. The click is identical each time; what differs is how much curved surface the count has to spend on.

How much does the triangle count cost in bytes at each preset?

Exactly 84 bytes of header plus 50 bytes per triangle, so the byte cost follows the count and nothing else: the flat cube is 684 bytes at all three presets, the rounded cube goes 2,084, 2,884 and 7,084 bytes, and the cone goes 14,384, 25,884 and 107,184 bytes from Draft to Fine. Read backwards, (7,084 - 84) / 50 returns 140 and (107,184 - 84) / 50 returns 2,142, which is why the finished file is a ledger of the count rather than a separate quality measure. The 84 and the 50 are the format's numbers and identical for every binary writer; the count they multiply is the geometry's, moved here by this site's three presets. The same preset that is worth three 684-byte files on flat parts is worth a 92,800-byte gap from Draft to Fine on the cone.

The judgement, in four moves before the cut

  1. Look at the part, not at the file. If the faces are all flat, Draft is the right answer and the choice costs nothing: 12 triangles, 684 bytes, at every setting. No setting can improve a planar face, because a plane is stored exactly.
  2. Start curved parts at Normal. On the cone that is 516 triangles and, by the fixed identity, 25,884 bytes. Preview it at your print's layer height and judge the curved faces, not the flat ones — the flat faces cannot complain at any setting.
  3. Still faceted on the curve? That is what Fine is for. The same cone at Fine is 2,142 triangles — 107,184 bytes, 7.5 times the Draft count of 286 — with the deviations tightened to 0.001 linear and 0.1 angular. On flat geometry Fine buys nothing; on curved geometry it is the tier that buys smoothness.
  4. Collect what you paid for. (size − 84) ÷ 50 must return the count you expected; the identity has no rounding, so a mismatch is a real fault, not an artefact. That arithmetic is check 1 on the verification page. It assumes a binary STL, though: an ASCII file spells the coordinates out as text and breaks the identity, which is what the binary-or-ASCII page measures on both writers.

Fine is not a guarantee: whichever deviation binds first decides

Each setting is a pair of numbers — a linear deviation and an angular one (Draft 0.02 and 0.5, Normal 0.005 and 0.3, Fine 0.001 and 0.1; these are this site's own choices, not a CAD standard, and npm test diffs them against the shipped engine). The pair interacts, and the count lands wherever the tighter constraint binds. On the cone at Fine's angular value, the linear number makes no difference at all: linear 0.02, 0.005 and 0.001 all give 2,142 triangles. Relax the angular value to 1.0 and the same three linear values give 186, 408 and 1,318 — tightening the linear deviation further adds nothing the angular constraint refuses. So “I set Fine, therefore I got the maximum” is not a promise this page can make: the count depends on which of the two numbers binds first, which the coupling grid on the workflow page measures cell by cell.

The pair is old, but the freedom to set it is newer than the files. An October 2006 desktop module list sells “full control of resolution” as a bullet inside an optional translator module rather than as part of the base licence — choosing how finely a surface becomes triangles was a line item once (the module list is read on the mesh-era page). Three fixed presets are the part of that old purchase that stopped being worth charging for; they are not the maximum, which is why the next paragraph exists.

One thing that does not move the count: the flavour word in the file header. The two AP203 / AP214 test assemblies ran through the same reader and the same three presets here, and their counts differ (+27.3 / +21.1 / +18.3%) only because the two exporters wrote the parts' B-rep differently — not because AP214 is a “higher quality” protocol. The budget rule is unchanged either way: the flavours page runs that comparison in full.

Cone triangle counts for one linear ladder under two angular deviations, all bars on one scale Six bars share one scale of 1 pixel = 5 triangles. In the top group, at the Fine preset's angular value of 0.1, all three bars are the same 2,142 triangles: linear 0.02, 0.005 and 0.001 all read 428 pixels. In the bottom group, at angular 1.0, the same three linear values finally separate: 186, 408 and 1,318 triangles, drawn as 37, 82 and 264 pixels. Whichever deviation binds first decides the count conical-surface.step, all six bars on one scale: 1 px = 5 triangles angular 0.1 (the Fine preset) — the angular constraint binds linear 0.02 → 2,142 linear 0.005 → 2,142 linear 0.001 → 2,142 angular 1.0 (the Coarse value) — the linear constraint binds linear 0.02 → 186 linear 0.005 → 408 linear 0.001 → 1,318 same three linear values in both groups; only the angular value moved.
Same linear ladder, two angular ceilings. Top: at the Fine preset's angular value of 0.1 the angular constraint binds, so the linear number is irrelevant and all three bars read 2,142. Bottom: relax the angular value to 1.0 and the same three linear values finally show their ladder, 186 → 408 → 1,318. “I set Fine, therefore I got the maximum” does not survive this pair of drawings: the count lands wherever the tighter deviation binds first.

What chordal distance and angle should I use when I export the STL myself?

Use the same pair this site uses: a linear deviation of 0.02, 0.005 or 0.001 together with an angular deviation of 0.5, 0.3 or 0.1 radians, tightened together rather than one at a time. On flat geometry the pair costs nothing, and the bill only appears where the part curves: the flat cube stays at 12 triangles at all three steps, the rounded cube goes 40, 56, 140 and the cone goes 286, 516, 2,142. Two cautions travel with the recipe. In this converter the linear number is a ratio of the model's bounding box rather than a millimetre figure, so the same digit is a different absolute distance on a different part; an exporter that asks for a chord height in millimetres is asking for another quantity, and the two agree only on a part of one particular size. And some exporters expose a single quality slider that computes both numbers for you without showing them, which leaves the output triangle count as the only figure you can compare across tools. Check an export by that count at the setting you intend to print, and recover it from the finished binary file with (size - 84) / 50.

A preset name is two numbers with two units

Every preset in this converter is a pair, and its two halves are not measured in the same thing. The linear number is a ratio of the model’s bounding box — a bare factor, no unit of its own — while the angular number is an angle, expressed here in radians, the unit the STEP to STL converter prints beside its custom field. The control reduces both to one name, so the name carries two quantities; the split of who owns that name is drawn on the resolution-label page, and the two numbers’ one-to-one grid is on the workflow page.

One preset name, two numbers, two units, and the count they produce together on the cone. Degrees are the radians × 180 ÷ π, computed by npm test; the counts are the same live cells as the tables above.
Preset nameLinear number (a ratio, unitless)Angular number (radians)Angular number in degreesCone triangles
Draft0.020.5 rad28.6°286
Normal0.0050.3 rad17.2°516
Fine0.0010.1 rad5.7°2,142

Which half a label is carrying shows up when you move one number and hold the other. Hold the angular number at the Fine value of 0.1 and walk the linear number 0.02 → 0.005 → 0.001: all three runs come back at 2,142 triangles and 107,184 bytes, so on this part the linear half is worth zero and the angular half is doing all the work. Then hold the linear number at 0.001 and walk the angular number 0.1 → 1.0: the same part falls to 1,318 triangles, 65,984 bytes — 824 triangles and 41,200 bytes bought by the angular half alone. Two numbers, two directions of movement, one label.

Which gives the rule to carry to another tool: a triangle count answers to both numbers; the byte size answers only to the count. Three different linear values produced one count and therefore one byte size, so the finished file cannot record which of the pair you moved — and a page or an exporter that prints one number under one unit (a chord height in millimetres, a single angle in degrees) is showing half the pair and leaving the other half unstated. The one figure that survives that comparison is the count, recovered from the finished binary with (size − 84) ÷ 50, which is check 1 on the verification page.

Four reproducible lines behind the pair argument: the units, then one direction of movement at a time
UnitsLinear 0.02 / 0.005 / 0.001 is a ratio of the bounding box, no unit of its own; angular 0.5 / 0.3 / 0.1 is radians → 28.6° / 17.2° / 5.7° at 180 ÷ π.
Linear half onlyCone with the angular number fixed at 0.1: 0.02, 0.005 and 0.001 all give 2,142 triangles → 84 + 50 × 2,142 = 107,184 bytes three times over; zero bytes moved.
Angular half onlyCone with the linear number fixed at 0.001: angular 0.1 → 1.0 gives 2,142 → 1,318 triangles, 824 fewer, → 84 + 50 × 1,318 = 65,984 bytes, and 107,184 − 65,984 = 41,200 bytes fewer.
The ruleBytes are 84 + 50 × triangles with no other input, so two pairs landing on the same count are the same file size: a byte count cannot say which number of the pair you changed.
One preset label split into its two numbers, then each number moved while the other is held The label Fine splits into two quantities: 0.001 of the model bounding box, which has no unit of its own, and 0.1 radians, which is 5.7 degrees. Holding the angular number at 0.1, the linear values 0.02, 0.005 and 0.001 all return one bar of 2,142 triangles and 107,184 bytes, a move of zero bytes. Holding the linear number at 0.001, the angular value 0.1 returns 2,142 triangles and 107,184 bytes while 1.0 returns 1,318 triangles and 65,984 bytes, a fall of 824 triangles and 41,200 bytes. Bars share one scale of 1 pixel to 6 triangles. One label, two numbers, two units Counts and bytes below are the tables’ own cells; bars share one scale, 1 px = 6 triangles. Fine 0.001 — a ratio of the bounding box, no unit of its own 0.1 rad — an angle, 5.7° at 180 ÷ π Move the linear number only — three values, one bar 2,142 tri · 107,184 B 0.02, 0.005 and 0.001 at angular 0.1 all land on this bar: zero bytes moved. Move the angular number only — linear held at 0.001 0.1 → 2,142 tri · 107,184 B 1.0 → 1,318 tri · 65,984 B −824 triangles, −41,200 bytes — the file records the count, not which half moved.
Same label, two quantities, one visible number. The name Fine hides a ratio and an angle, and the two behave differently: the linear half alone is worth zero bytes on this part, while the angular half alone is worth 824 triangles and 41,200 bytes. Because the bytes follow only the count (84 + 50 × triangles), a finished file cannot say which half of the pair you moved — only that the count landed where the tighter number allowed.

Is a quality preset one number or two?

A preset is a pair of numbers with two different units: a linear deviation, which this converter expresses as a ratio of the model's bounding box and therefore carries no unit of its own, and an angular deviation, in radians. The control shows the pair under one name, Draft 0.02 and 0.5, Normal 0.005 and 0.3, Fine 0.001 and 0.1, and those angular values are 28.6, 17.2 and 5.7 degrees. The count answers to both numbers; the bytes answer only to the count. On the cone, moving the linear number alone from 0.02 to 0.001 at the Fine angular value leaves all three runs at 2,142 triangles and 107,184 bytes, while moving the angular number alone from 0.1 to 1.0 at linear 0.001 drops the part from 2,142 to 1,318 triangles, a fall of 41,200 bytes. A label that prints one number under one unit therefore carries half of the pair, and no byte count can tell you which half you changed.

The label you click and the number the engine reads are two different layers

A quality control can hold three numbers at once, and a page can print two of them while the third does all the work. One is a word for the visitor. One is a cap for the operator. The third is the value the engine actually receives — and on one benchmark converter, read on , that third layer travels in the page’s own markup: the three tiers show word labels beside per-tier caps, while the quantity that decides the mesh reaches the engine unexplained, in no unit the page names. The first two layers are printed; the only layer that moves the triangle count is not.

Which of the three can a reader audit? The word binds to nothing: no unit, no pair, no count it can predict. The cap prices the file, not the mesh. The engine-facing value decides the triangles, and it is the one layer the page does not explain — so on such a page nothing can be re-run: not a tolerance, not a count, not a byte. The single figure that survives is the count inside the finished file, (size − 84) ÷ 50: it reports what the unprinted value did without ever showing what it was.

This converter’s choice is the opposite: the deciding layer is printed. The three presets carry their full pair beside the name — Draft 0.02 and 0.5, Normal 0.005 and 0.3, Fine 0.001 and 0.1 — and that printed pair is the pair the engine receives: the suite re-diffs the values the page shows against the values the engine is sent, on every run. There is no second layer to audit here: what the label says, the field shows, the engine gets, and the bytes let you check afterwards — the same audit the pair section above runs one layer down.

The neighbouring questions live elsewhere: which owner a resolution label answers to is the resolution-label page’s three-way split; the two deviation boxes in a slicer dialog are the slicer page’s knobs; whether a printed number is a service constant is the size-limit page’s two classes. This section asks only the layer question: what you see, what the machine reads, and which of the two you can re-run.

Three reproducible lines: the printed pair, the audit it enables, and what a bare label supports
Printed pairDraft 0.02 + 0.5 rad, Normal 0.005 + 0.3 rad, Fine 0.001 + 0.1 rad — the same values the engine receives; the suite re-diffs both sides on every run.
The audit it enablesCone at Fine: 2,142 triangles → 84 + 50 × 2,142 = 107,184 bytes; read back, (107,184 − 84) ÷ 50 = 2,142 — predicted from the printed pair, re-earned from the bytes.
From a bare labelA word with no printed pair writes no identity: no unit, no count to predict, no byte to check — nothing to re-run.
Two designs for the same quality control: the deciding value printed, or the deciding value hidden Two panels. The left panel shows a control that displays only a tier word: the engine also receives a value the page never explains and no unit names, so nothing on it can be re-run. The right panel shows this site's control printing its full pair beside the name: the engine receives exactly the printed pair, and the byte identity re-earns the count. No figure from any other site appears. What the label shows and what the engine reads Two designs for the same control. Both send a value to the engine; only one prints it. a control that shows a word only a tier word behind it, the engine receives a value the page never explains and no unit names → nothing printed here can be re-run this control: word and pair, printed Fine — 0.001 + 0.1 rad the engine receives exactly that printed pair; the suite re-diffs both sides on every run → (bytes − 84) ÷ 50 re-earns the count Same click, same engine, one auditable difference. A word binds to nothing; a printed pair answers to the bytes.
The deciding layer, printed or not. Both controls hand a value to the engine; only the right-hand design prints it, and printing it is what makes the audit possible: predict the count from the pair, then recover it from the finished bytes with (size − 84) ÷ 50.

Is the setting I click the number the engine actually receives?

Here, yes. The three presets print their full pair beside the name - Draft 0.02 and 0.5, Normal 0.005 and 0.3, Fine 0.001 and 0.1 - and that printed pair is what the engine receives: the suite re-diffs the values the page shows against the values the engine is sent on every test run, and the finished bytes let you check the result with (size - 84) / 50. A control that shows only a word can be the opposite: on one benchmark converter read on 25 November 2026, the value its markup sends the engine is never explained and no unit names it, so the number that decides the mesh sits one layer below everything printed. The figure that still reports what it did is the triangle count recovered from your own output.

How close the mesh is: convergence you can measure

Triangle counts say how much the mesh spends; the next question is how close it lands. Two measurements answer that, both computed from the mesh itself. The first is volume: a flat cube's mesh encloses exactly 1,000.000 mm³ at every setting, because planes are stored exactly — which makes the cube the self-check. Curved parts start below the true surface and climb as the preset tightens:

Mesh volume at the three presets, in mm³, computed from the output triangles by the same auditStats() code the converter's audit panel runs; npm test re-runs every cell. These are mesh approximations — the kernel exposes no B-rep mass properties — and the true surface value sits at or above each column.
ShapeDraftNormalFineDraft → Fine
All-flat part (a cube)1,000.0001,000.0001,000.000exact
Cube with rounded edges944.705827945.682894946.270698+0.17%
Curved surface (a cone)2,507.3327862,515.2658522,519.272018+0.47%

The more curvature a part holds, the wider the spread: the rounded cube's mesh volume climbs 0.17% from Draft to Fine, the cone's 0.47%. That spread is a measurable proxy for how much surface the mesh is still approximating — the same ordering the triangle budget shows, read from a different direction.

The second measurement goes further and needs one honest precondition. On a test piece whose surface is analytically known — and it is known here because a STEP file is text: the cone sample declares its CONICAL_SURFACE semi-angle, radius and axis in plain view — every cone-face triangle's interior can be sampled and its closed-form distance to the true cone taken. The maximum over the mesh is a measured chordal deviation: 0.174179 mm at Draft, 0.057284 mm at Normal, 0.009414 mm at Fine, each under the deflection the preset requested, across 43, 128 and 670 cone-face triangles. The boundary of the claim matters as much as the number: this measurement exists for test pieces whose geometry the file text declares, never for arbitrary user files — for those, the converter's audit panel reports the mesh's own volume and surface area, labelled as mesh approximations, plus boundary-edge, shell and degenerate-triangle counts.

File size cannot tell you the count — in either direction

Two measurements to keep beside the budget. First, the input's size is unrelated to the output's count: the cone's STEP file is 9,391 bytes, and at Normal it writes a 25,884-byte STL, at Fine a 107,184-byte one. Second, the part's physical size is unrelated too: scale that same cone to 100× its size and the bounding box grows from 27.033 mm to 2,703.298 mm, while the triangle counts stay exactly 286, 516 and 2,142 at every setting — measured at both sizes on the workflow page. That is why choosing a quality tier by output file size runs backwards: size is the consequence of the count, never its cause. One of the three benchmark sites this project tracks prices its quality tiers as output file-size caps, which cannot tell you how many triangles a given part will get; the count answers to curvature and deviation, and you read it back from the bytes after the one cheap, local conversion.

Why the three benchmark sites cannot answer this

Of the three sites this project tracks — polyd.com, convert3d.org and imagetostl.com — none puts a triangle count or a deviation pair anywhere a converting reader can see one. polyd's converter page offers its three tiers as output file-size caps with a maximum-size label, which prices the file rather than the mesh. convert3d's STEP page is a two-row compatibility table with no quality dimension at all. imagetostl does publish a STEP-to-STL page now — read on — and it still leaves the count out of reach: no triangle count, no deviation pair and no quality dimension, only a file-size limit and a batch limit. The cell they leave empty is the one this page occupies: a way to decide the triangle question before the cut and to verify it after, with measured numbers.

What would a speed claim need before a reader could repeat it? Three things: what the conversion is a multiple of, how big the file was, and which machine did the work. A multiple printed without the baseline it divides by, or a time printed without the size of the file it was timed on, hands the reader a number with no denominator — and an accuracy sentence that offers an adjective where a tolerance belongs is the same failure in a different dress. This page stays dull on purpose: it prints a triangle count, a byte count and a deviation figure, and all three can be recomputed from the file in front of you.

Can a sample picture on a converter page tell you its triangle count? No. The pictures a conversion site usually ships — the same sphere shown at low, medium and high — differ in how round the silhouette looks, and a silhouette drawn for the page is not the mesh you will download. polyd’s resolution article, read on 2026-11-03, pairs its three tiers with one sphere photographed from the same angle and gives its numbers in degrees of shape deviation, not in triangles; useful for seeing what deviation does, silent on the count. The count only exists in the file, and the file can be counted: the cube above stays at 12 triangles at every stop while the cone runs 286 / 516 / 2,142, so two parts on one page can come back with two different answers to the same question.

Can a triangle count printed beside a sample file be used as a budget for my part? Only as an anecdote, never as a budget. One benchmark site, read on , offers a downloadable sample model with a sentence saying how many triangles it contains once converted — a rounded number in the thousands, given to one small file, with no deviation pair printed beside it. That number is one writer’s result on one shape, and it does not travel: here the flat cube stays at 12 triangles at all three presets while the cone runs 286 / 516 / 2,142 at those same three, a spread of 214× inside one page. A budget has to move with curvature and with the preset, so the only count worth planning against is the one that comes back from your own file — (bytes − 84) ÷ 50 after one local conversion.

A rounded count printed beside a downloadable sample, next to the count read from your own file On the left, a page shipping one sample file with a rounded triangle number and no preset. On the right, the byte identity applied to your own output. Below, the cube at twelve triangles beside the cone at three preset counts. A sample’s count is a result, not a budget One number for one file, printed without the preset that produced it. a page’s sample file one rounded count, in the thousands no deviation pair, no preset shown vs your file, your preset (bytes − 84) ÷ 50 684 bytes returns 12 triangles Cube: 12 at Draft, Normal and Fine. Cone: 286 / 516 / 2,142 at the same three. A 214× spread on one page; no single sample number survives it. Counts here are re-run by npm test from the shipped engine.
Same word, different quantity. A count printed beside a sample records what one writer did to one shape; a budget has to answer what your shape needs at your preset. The cube and the cone on this page are converted by the same engine at the same three presets and land 214× apart, which is why the number to plan against is the one read back from your own output.

Where these numbers come from

npm test

The command above re-runs every number on this page. The workflow page owns the six steps in order and the full cost table; the verification page owns the six checks, check 1 being the count from the bytes; and the STEP to STL converter is where the one cheap conversion runs — in your tab, with nothing uploaded.